WA-150DT
Flow range: 5-150 L/min (ANR)
- Air port Rc1/4 (8A)
- Drain outlet 6 mm hose nipple
- Weight 0.59 kg
WELL AIR is an element-free compressed-air purifier that separates water droplets, oil droplets, and foreign matter near the point of use. For international markets, the DT Series is available in three flow capacities to suit different equipment requirements.
First select the DT model according to the actual air consumption of the equipment. Then determine whether additional treatment is required for fine particles, oil mist, or water vapor.
Select the model according to the actual air consumption of the end-use equipment, rather than selecting only by pipe connection size. Allow sufficient capacity for operating fluctuations.
The DT Series separates water droplets, oil droplets, and foreign matter. For fine particles or oil mist, use the WELL AIR CLEAN configuration.
If lower-dew-point air is required, select the WELL AIR DRY configuration. Final selection depends on inlet conditions, flow rate, pressure, and required air quality.
International markets: The WELL AIR base unit is supplied in the DT specification. Availability of WELL AIR CLEAN, WELL AIR DRY, and downstream components may vary by destination.
North America: Product information is currently provided through the North America catalog.
International models for drain containing water, oil, and foreign matter
The DT Series is the standard WELL AIR specification supplied for international markets. It separates water droplets, oil droplets, and foreign matter from compressed air near the point of use without using a replaceable filter element.
Flow range: 5-150 L/min (ANR)
Flow range: 20-400 L/min (ANR)
Flow range: 70-1,200 L/min (ANR)
| Item | WA-150DT | WA-400DT | WA-1200DT |
|---|---|---|---|
| Flow range L/min (ANR) | 5-150 | 20-400 | 70-1,200 |
| Air piping connection | Rc1/4 (8A) | Rc3/8 (10A) | Rc3/4 (20A) |
| Drain outlet | 6 mm hose nipple | ||
| Operating pressure range | 0.1-1.0 MPa | ||
| Proof pressure | 1.5 MPa | ||
| Fluid temperature | 5-65°C | ||
| Weight | 0.59 kg | 1.11 kg | 2.79 kg |
* Performance values are based on internal tests and may vary depending on inlet conditions, flow rate, pressure, temperature, and contaminant properties.
* WELL AIR does not remove water vapor or oil vapor. If fine particles, oil mist, or lower-dew-point air must also be treated, consider WELL AIR CLEAN or WELL AIR DRY.
Dimensional drawings are available after submitting the short document-download form. Large-flow and special specifications, including WA-2500DT, are introduced separately below.
WELL AIR CLEAN and WELL AIR DRY are staged compressed-air treatment configurations built around WELL AIR. Select the configuration according to whether the application also requires treatment of fine particles, oil mist, or water vapor.
Precision Filter Set
WELL AIR first separates water droplets, oil droplets, and coarse foreign matter. The precision filter then treats fine particles and oil mist.
This configuration is suitable for precision processing, painting, coating, and high-quality air-blow applications that require a higher air-quality level than WELL AIR alone.
| Item | WA-400DT-MS | WA-1200DT-MS |
|---|---|---|
| Air connection | Rc3/8 (10A) | Rc3/4 (20A) |
| Maximum flow rate | 400 L/min (ANR) | 1,200 L/min (ANR) |
| Operating pressure range | 0.1-1.0 MPa | |
| Fluid temperature range | 5-60°C | |
| Nominal precision-filter rating | 0.01 μm | |
| Outlet oil-mist concentration | ≤0.1 mg/m³ | |
* The nominal filtration rating and outlet oil-mist concentration are the published values of the selected precision filter. Performance of the complete configuration varies according to operating conditions.
Low-Dew-Point Set
WELL AIR and the precision filter treat liquid droplets, coarse foreign matter, fine particles, and oil mist in stages. The membrane air dryer then reduces water vapor.
This configuration is suitable for precision measurement, condensation prevention, and equipment that requires lower-dew-point compressed air.
| Item | WA-400DT-MD | WA-1200DT-MD |
|---|---|---|
| Air connection | Rc3/8 (10A) | Rc3/4 (20A) |
| Operating pressure range | 0.3-1.0 MPa | |
| Inlet air temperature range | 5-50°C | |
| Nominal precision-filter rating | 0.01 μm | |
| Outlet oil-mist concentration | ≤0.1 mg/m³ | |
| Outlet atmospheric dew point | Approx. -20°C | |
* The atmospheric dew point of approximately -20°C is a reference value at an inlet pressure of 0.7 MPa, inlet air temperature of 25°C, inlet-air saturation temperature of 25°C, and ambient temperature of 25°C. It is not a guaranteed value. Actual dew point, outlet flow, and purge-air flow vary according to operating conditions.
For international markets, WELL AIR CLEAN and WELL AIR DRY are configured using DT-specification WELL AIR units. Availability of filters, membrane air dryers, and complete assemblies may vary by destination.
Select the appropriate piping components and mounting bracket according to the WELL AIR model and installation conditions.
Piping component sets are available for WA-400-type installations.
| Piping Component Sets for WA-400 Type | ||
|---|---|---|
| Model | pp-n | pp-s |
| Specification | 3/8 nipple | 3/8-1/2 reducing socket |
Confirm the required piping arrangement, connection size, and availability for the destination market before ordering.
Dedicated mounting brackets are available according to the WELL AIR model size.
| Model | u-150 | u-400 | u-1200 |
|---|---|---|---|
| Description | Bracket for WA-150 type | Bracket for WA-400 type | Bracket for WA-1200 type |
Mounting brackets are optional components. Select the bracket that corresponds to the installed model.
Installation conditions vary according to the equipment, piping layout, operating environment, and selected configuration. Please contact us if you require assistance with model selection or installation planning.
Tell us the required flow rate, inlet pressure, inlet temperature, drain condition, installation environment, and target air quality. We will review the operating conditions and help identify an appropriate WELL AIR model and treatment configuration.