WELL AIR Product Lineup

WELL AIR LINEUP

WELL AIR is an element-free compressed-air purifier that separates water droplets, oil droplets, and foreign matter near the point of use. For international markets, the DT Series is available in three flow capacities to suit different equipment requirements.

International markets: DT Series
North America: Catalog information only
DT Series WELL AIR CLEAN / DRY Large Flow / Special Specifications Optional Components Installation Notes Contact

How to Choose

First select the DT model according to the actual air consumption of the equipment. Then determine whether additional treatment is required for fine particles, oil mist, or water vapor.

Step 01

Select by Flow Rate

Select the model according to the actual air consumption of the end-use equipment, rather than selecting only by pipe connection size. Allow sufficient capacity for operating fluctuations.

Step 02

Confirm the Treatment Target

The DT Series separates water droplets, oil droplets, and foreign matter. For fine particles or oil mist, use the WELL AIR CLEAN configuration.

Step 03

Confirm the Required Air Quality

If lower-dew-point air is required, select the WELL AIR DRY configuration. Final selection depends on inlet conditions, flow rate, pressure, and required air quality.

DT Series Flow Guide
WA-150DT Flow range: 5-150 L/min (ANR)
WA-400DT Flow range: 20-400 L/min (ANR)
WA-1200DT Flow range: 70-1,200 L/min (ANR)
Select the configuration according to the required air quality
WELL AIR Separates water droplets, oil droplets, and coarse foreign matter.
WELL AIR CLEAN Combines WELL AIR with a precision filter for fine particles and oil mist.
WELL AIR DRY Adds a membrane air dryer when lower-dew-point air is required.

International markets: The WELL AIR base unit is supplied in the DT specification. Availability of WELL AIR CLEAN, WELL AIR DRY, and downstream components may vary by destination.

North America: Product information is currently provided through the North America catalog.

Model Selection Notes
Select the model based on the actual air consumption, inlet pressure, inlet temperature, piping conditions, and required air quality of the end-use equipment. If the operating flow may approach the maximum rated flow, select the next larger model or contact us for application-specific model selection.

DT Series

International models for drain containing water, oil, and foreign matter

3 Models

The DT Series is the standard WELL AIR specification supplied for international markets. It separates water droplets, oil droplets, and foreign matter from compressed air near the point of use without using a replaceable filter element.

  • Separates water droplets, oil droplets, and solid contaminants through high-speed swirling airflow and impaction
  • Does not use a replaceable filter element or desiccant
  • Operates without electricity or an external heat source
  • Equipped with an automatic drain for separated liquid
  • Designed for installation near the end-use equipment
  • Periodic inspection is recommended according to operating conditions
WELL AIR WA-150DT

WA-150DT

Flow range: 5-150 L/min (ANR)

  • Air port Rc1/4 (8A)
  • Drain outlet 6 mm hose nipple
  • Weight 0.59 kg
Download Drawing: WA-150DT
WELL AIR WA-400DT

WA-400DT

Flow range: 20-400 L/min (ANR)

  • Air port Rc3/8 (10A)
  • Drain outlet 6 mm hose nipple
  • Weight 1.11 kg
Download Drawing: WA-400DT
WELL AIR WA-1200DT

WA-1200DT

Flow range: 70-1,200 L/min (ANR)

  • Air port Rc3/4 (20A)
  • Drain outlet 6 mm hose nipple
  • Weight 2.79 kg
Download Drawing: WA-1200DT

DT Series Specifications

Item WA-150DT WA-400DT WA-1200DT
Flow range L/min (ANR) 5-150 20-400 70-1,200
Air piping connection Rc1/4 (8A) Rc3/8 (10A) Rc3/4 (20A)
Drain outlet 6 mm hose nipple
Operating pressure range 0.1-1.0 MPa
Proof pressure 1.5 MPa
Fluid temperature 5-65°C
Weight 0.59 kg 1.11 kg 2.79 kg
Water / drain separation 99.99%
Liquid oil / oil-droplet separation 99.99%
Solid particles 3 μm or larger 99.99%

* Performance values are based on internal tests and may vary depending on inlet conditions, flow rate, pressure, temperature, and contaminant properties.

* WELL AIR does not remove water vapor or oil vapor. If fine particles, oil mist, or lower-dew-point air must also be treated, consider WELL AIR CLEAN or WELL AIR DRY.

Dimensional drawings are available after submitting the short document-download form. Large-flow and special specifications, including WA-2500DT, are introduced separately below.

Air Quality Configurations

Add treatment according to the required air quality.

WELL AIR CLEAN and WELL AIR DRY are staged compressed-air treatment configurations built around WELL AIR. Select the configuration according to whether the application also requires treatment of fine particles, oil mist, or water vapor.

WELL AIR CLEAN

Precision Filter Set

WELL AIR + Precision Filter

WELL AIR first separates water droplets, oil droplets, and coarse foreign matter. The precision filter then treats fine particles and oil mist.

This configuration is suitable for precision processing, painting, coating, and high-quality air-blow applications that require a higher air-quality level than WELL AIR alone.

  • Staged treatment using WELL AIR and a precision filter
  • Treats fine particles and oil mist after bulk liquid separation
  • Nominal precision-filter rating of 0.01 μm
  • ISO 8573-1 system target: [1:4:2]
Nominal filtration rating 0.01 μm
Outlet oil-mist concentration ≤0.1 mg/m³
ISO 8573-1 system target [1:4:2]
WELL AIR CLEAN WA-400DT-MS
WA-400DT-MS WELL AIR CLEAN configuration
WELL AIR CLEAN WA-1200DT-MS
WA-1200DT-MS WELL AIR CLEAN configuration
Item WA-400DT-MS WA-1200DT-MS
Air connection Rc3/8 (10A) Rc3/4 (20A)
Maximum flow rate 400 L/min (ANR) 1,200 L/min (ANR)
Operating pressure range 0.1-1.0 MPa
Fluid temperature range 5-60°C
Nominal precision-filter rating 0.01 μm
Outlet oil-mist concentration ≤0.1 mg/m³

* The nominal filtration rating and outlet oil-mist concentration are the published values of the selected precision filter. Performance of the complete configuration varies according to operating conditions.

WELL AIR DRY

Low-Dew-Point Set

WELL AIR + Precision Filter + Membrane Air Dryer

WELL AIR and the precision filter treat liquid droplets, coarse foreign matter, fine particles, and oil mist in stages. The membrane air dryer then reduces water vapor.

This configuration is suitable for precision measurement, condensation prevention, and equipment that requires lower-dew-point compressed air.

  • WELL AIR separates water droplets, oil droplets, and coarse foreign matter
  • The precision filter treats fine particles and oil mist
  • The membrane air dryer reduces water vapor
  • Outlet atmospheric dew point reference: approximately -20°C
Nominal filtration rating 0.01 μm
Atmospheric dew point reference Approx. -20°C
ISO 8573-1 system target [1:Selected:2]
WELL AIR DRY WA-400DT-MD
WA-400DT-MD WELL AIR DRY configuration
WELL AIR DRY WA-1200DT-MD
WA-1200DT-MD WELL AIR DRY configuration
Item WA-400DT-MD WA-1200DT-MD
Air connection Rc3/8 (10A) Rc3/4 (20A)
Operating pressure range 0.3-1.0 MPa
Inlet air temperature range 5-50°C
Nominal precision-filter rating 0.01 μm
Outlet oil-mist concentration ≤0.1 mg/m³
Outlet atmospheric dew point Approx. -20°C

* The atmospheric dew point of approximately -20°C is a reference value at an inlet pressure of 0.7 MPa, inlet air temperature of 25°C, inlet-air saturation temperature of 25°C, and ambient temperature of 25°C. It is not a guaranteed value. Actual dew point, outlet flow, and purge-air flow vary according to operating conditions.

For international markets, WELL AIR CLEAN and WELL AIR DRY are configured using DT-specification WELL AIR units. Availability of filters, membrane air dryers, and complete assemblies may vary by destination.

Options and Installation

Optional components and installation notes

Select the appropriate piping components and mounting bracket according to the WELL AIR model and installation conditions.

Optional Piping Components

Piping component sets are available for WA-400-type installations.

Piping Component Sets for WA-400 Type
Model pp-n pp-s
Specification 3/8 nipple 3/8-1/2 reducing socket

Confirm the required piping arrangement, connection size, and availability for the destination market before ordering.

Mounting Brackets

WELL AIR mounting brackets

Dedicated mounting brackets are available according to the WELL AIR model size.

Model u-150 u-400 u-1200
Description Bracket for WA-150 type Bracket for WA-400 type Bracket for WA-1200 type

Mounting brackets are optional components. Select the bracket that corresponds to the installed model.

Bracket Drawing: u-150 Bracket Drawing: u-400 Bracket Drawing: u-1200
Installation

WELL AIR Installation Notes

  1. Always install WELL AIR vertically.
  2. Install WELL AIR as close as practical to the end-use pneumatic equipment.
  3. Whenever possible, provide sufficient piping distance from the compressor before installation. Approximately 20 m is a practical guideline.
  4. Confirm the airflow direction and do not reverse the IN and OUT connections.
  5. Install filters, regulators, lubricators, and other downstream treatment equipment after WELL AIR.
  6. Read the instruction manual carefully and confirm the applicable pressure, temperature, flow rate, piping, and drain conditions before installation and operation.

Installation conditions vary according to the equipment, piping layout, operating environment, and selected configuration. Please contact us if you require assistance with model selection or installation planning.

Model Selection Support

Need help selecting the right configuration?

Tell us the required flow rate, inlet pressure, inlet temperature, drain condition, installation environment, and target air quality. We will review the operating conditions and help identify an appropriate WELL AIR model and treatment configuration.

Contact Us View Catalogs and Drawings
International Markets Contact us to confirm model selection, configuration, and availability for your destination.
North America Product information is currently provided through the North America catalog.
Specifications, available configurations, and product appearance may change without prior notice for product improvement.

Company

KAMATA TECNAS CO., LTD.

1-1-25 Sanchiku, Hakata-ku
Fukuoka 812-0887, Japan

Tel: +81-92-571-2398

View Company Profile

Technical Columns

TROUBLE & CAUSE Why does water still appear after installing an air dryer? Why does condensation occur in compressed-air lines?
INDUSTRY Why does water appear in machine tools? Compressed-air problems in steel plants
SOLUTION & COMPARISON Why an air dryer alone may not prevent water problems Filter vs. element-less separation: what is the difference?
View all technical columns →

Get in Touch

Catalogs and dimensional drawings

Download Documents

WELL AIR product lineup

View Product Lineup

Model selection and custom requirements

Contact Us
Home / Products / Documents / Contact / Privacy Policy
© KAMATA TECNAS

Copyright © WELL AIR All Rights Reserved.

Powered by WordPress with Lightning Theme & VK All in One Expansion Unit

MENU
PAGE TOP