Any equipment that uses compressor air (compressed air) has potential demand.
It removes the moisture in the air pipe (compressed air).
It is used in a wide range of applications, including production equipment, processing equipment, and medical equipment.
■ Moisture removal
It is a "new air-water separation" that removes moisture at the end instead of centralized humidity control.
It is a method called "special collision separation method" developed independently.
This is a unique method that combines collision separation and centrifugal separation using the difference in specific gravity.
yes. Acquired domestically and internationally.
WELL AIR is unnecessary if condensation is completely prevented and water is removed.
By installing WELL AIR just before the terminal equipment, it is possible to remove generated moisture.
This is because condensation forms in the long pipe from the dryer in the compressor room to the terminal equipment.
It's your problem, but please check if there is really no water now.
■ Performance
0 to 0.5 kgf/cm2. No change over time.
Select a model that is one rank higher than the selected model.
It does not come out of WELL AIR, but it can occur in subsequent piping.
WELL AIR separates and removes drain by air-water separation. It does not dehumidify.
WELL AIR is not a dustproof device, but it can remove dust up to 5μ.
WELL AIR is not exclusively for oil removal, but it can remove liquid oils.
WELL AIR does not require replacement of parts and basically does not deteriorate in performance.
■ Specifications
The body of WELL AIR is made of die-cast aluminum.
There are four models, WA-150, WA-400, WA-1200, and WA-2500, depending on the flow rate used.
■Installation/Installation
no. Install one WELL AIR for each terminal device.
Install directly in front of the terminal equipment, not in the compressor room.
This is because it is not possible to remove water droplets that condense in the piping between the WELL AIR and the terminal equipment.
Keep it as short as possible to minimize the chance of condensation.
If installed horizontally, the performance will be adversely affected, so be sure to install it vertically.
This is caused by the air conditioning that has a temperature difference with the air inside the pipes. It is effective to prevent dew condensation by attaching heat insulating material to the piping.
Yes, it is an option for each model.
■ Maintenance and inspection
No maintenance required. There is no running cost or trouble after installation.
no. No filters are used, so there is no need to replace them.
The products we installed in our own facilities 20 years ago are still operating without problems.
It cannot be repaired, but it is structurally indestructible.
In the unlikely event that there is a defect due to an initial defect (one year), we will replace it.